Skip to main content

Table 3 Comparison of own results with numbers extracted from literature

From: Utilization of renewably generated power in the chemical process industry

  Onshore power generation Offshore power generation Photovoltaic systems
Results of own calculations
Gross power generation (TWh) 77.8 33.6 41
Full load hours (h/a) 2,000 3,350 770
Results extracted from [11]
Gross power generation (TWh) 82 33 45
Full load hours (h/a) 2,100 3,300 840
Relative deviation
Gross power generation (%) −2.75 +1.8 −8.9
Full load hours (%) −4.7 +1.5 −8.3