Table 7 Discount rate sensitivity results

From: Assessment of a decentralized grid-connected photovoltaic (PV) / wind / biogas hybrid power system in northern Nigeria

Discount rate NPC ($) LCOE ($/kWh)/Excel-based Operating costs ($/year)/Excel-based
4% 17.2 M 0.0812 148,491.8
5% 16.9 M 0.0799 145,857.7
6% 16.7 M 0.0788 142,339.8
7% 16.5 M 0.0778 138,046.0
8% 16.3 M 0.0769 133,081.9